The Cisco IE3300 Rugged Series is designed for industrial ethernet applications. They are ideal for manufacturing, energy, oil and gas, and transportation sectors. Their modular design allows you to adapt your device according to your needs. The IE-3300-8U2X-A offers high-density industrial PoE, enabling you to power your industrial devices. With IE-3300-8U2X-A, you can have Full Gigabit connectivity for high-speed applications.
Key Features:
- Network Advantage License
- PoE++ enabled
- 2 x 1GE/10G SFP+ Ports
Properties
Properties | Cisco IE-3300-8U2X-A |
Description | Catalyst IE3300 with 8 GE Copper (4PPoE) and 2 10G SFP, Modular, Network Advantage |
Product Family | Industrial Ethernet 3300 |
Product Type | Ethernet Switch |
Switches | |
Total Ports | 10 |
10/100/1000 RJ45 Copper Ports | 8 |
100/1000 SFP Ports | - |
1GE/2.5G RJ45 Copper ports | - |
1GE/10G SFP+ Ports | 2 |
Software License (Default) | Network Advantage |
PoE/PoE (+) budget | 480W |
Software Features | |
Network Essentials License (Perpetual) |
Features |
Layer 2 Switching | IEEE 802.1, 802.3 standard, NTP, UDLD, CDP, LLDP, unicast MAC filter, PAgP, LACP, VTPv2, VTPv3, EtherChannel, Q-in-Q tunneling, voice VLAN, PVST+, MSTP, and RSTP |
Multicast | IGMPv1, v2, v3 snooping, IGMP filtering, IGMP querier |
Managament | WebUI, MIB, SmartPort, SNMP, syslog, DHCP server, SPAN session, RSPAN, FSPAN, Express setup, NETCONF, RESTCONF |
Security | Port security, 802.1x, Dynamic Host Configuration Protocol (DHCP) snooping, dynamic ARP inspection, IP source guard, guest VLAN, MAC authentication bypass, 802.1x multidomain authentication, storm control - unicast, multicast, broadcast, SCP, SSH, SNMPv3, TACACS+, RADIUS server/client, MAC address notification, BPDU guard, Access Lists (PACL,VACL,RACL), SUDI 2099 (Secure Unique Device identifier), Full Flexible NetFlow (FNF), MACsec-128 |
Quality of Service (QoS) | Ingress policing, rate limit, egress queuing and shaping, auto QoS |
IPv6 | IPv6 host support, SNMP over IPv6, HTTP/HTTP(s) over IPv6, SNMP over IPv6, Syslog over IPv6, DHCPv6 relay source, DHCPv6 bulk lease query (RFC 5460), IPv6 stateless Auto Config SCP/SSH, Radius, TACACS+, NTP over IPv6, IPv6 VRF aware BGPv6, IPV6 ND cache expire, IPv6 support for TFTP, IPv6 DNS transport, IPv6 QoS, IPv6 FHS RA Guard, IPv6 FHS DHCPv6 Guard |
Layer 3 Routing | Inter-VLAN routing, Static routing |
Utility | Dying gasp, SCADA protocol classification - GOOSE messaging, MODBUS TCP/IP |
Industrial Ethernet | CIP Ethernet/IP, IEEE 1588 PTP v2 (default and power), PROFINET |
Redundancy | Resilient Ethernet Protocol (REP) ring, PROFINET-Media Redundancy Protocol (MRP), REP Preferred, Fast REP |
Automation | YANG, NETCONF, RESTCONF |
Industrial Management | Layer 2 switching with 1:1 switch Network Address Translation (L2NAT) |
IOx | Container (Native docker) |
Network Advantage License (Perpetual) | Features |
IP routing Protocols | OSPF (IPv4 and IPv6), BGP (v4 and v6), RIP (V1 and V2), ISIS (v4 and v6), EIGRP (v4 and v6), Policy based routing(PBR), VRRP(v4 and v6), HSRP(v4 and v6), BFD Echo Mode for OSPFv3 |
Virtualization | Vrf-lite |
Security | MACsec-256 |
IP Multicast | PIM sparse mode (PIM-SM), PIM dense mode (PIM-DM), PIM sparse dense mode, MSDP, Multicast routing BSR (IPv4/IPv6), Auto RP(IPv4), Embedded RP(IPv6) |
(Network Advantage License includes all Network Essentials Features.) | |
Dimensions (HxWxD) Inches | 6 in. X 4.4 in. X 5.3 in. 15.2 cm. x 11.2 cm. x 13.5 cm |
Weight | 4.5 lbs (2.0 kg) |
Mounting | DIN Rail |
Cisco DNA Features | |
Cisco DNA Essentials | Cisco DNA Advantage |
Element Management Discovery, Topology, Inventory, software image management |
Element Management Discovery, Topology, Inventory, software image management |
Basic Assurance Health dashboard - Network, Client monitoring; switch and wired client health monitoring |
Basic Assurance Health dashboard - Network, Client monitoring; switch and wired client health monitoring |
Basic Automation Cisco Network Plug-and-Play application |
Basic Automation Cisco Network Plug-and-Play application |
- | Assurance and Analytics Compliance, Custom Reports, Device 360 and Client 360 -Display device and client connectivity for granular troubleshooting |
- | Element Management Patch/SMU |
- | Software-define Access Policy based automation and assurance for wired clients, IE3300 can function as an SD-Access extended node REP ring Workflow |
Specifications
Specifications | IE-3300-8U2X-A |
DRAM | 4 GB |
Flash Memory | 1.5 GB |
Hardware | |
PoE power budget | Up to 480W(including expansion module) |
Removable storage | USB (Optional), SD card (Optional) |
Alarms | 2 alarms in, 1 alarm out |
Console ports | 1 RS-232 (via RJ-45), 1 USB Mini Type B |
Power inputs | Dual DC power inputs |
Number of Queues | 8 |
Forwarding Rate | Line rate for all ports and all packet sizes |
Unicast MAC addresses | 8000 |
Jumbo Frames | 8996 bytes |
No. of VLANs | 256 |
IPv4 Indirect routes | 2000 |
IPv6 Indirect routes | 512 |
Internet Group Managament Protocol (IGMP) Multicast Groups | 1000 |
Spanning Tree Protocol (STP) instances |
128 |
Access Control Entries (PACL/VACL/RACL) |
3000 |
SD card capacity (Optional) | 4 GB |
Input Voltage Range | Redundant DC input voltage: 9.6 to 60VDC 48VDC is required for PoE and 54VDC is required for PoE+ / 4PPoE |
Maximum Input Current | 10.5A |
Power Consumption | 42W |
Operating Temperature | -40°C to +70°C (40 LFM vented enclosure) -40°C to +60°C (sealed enclosure) -34°C to +75°C (Min. 200 LFM fan or blower-equipped enclosure) +85°C (type tested for 16 hours) |
Storage Temperature | -40 C to +85 C |
Operating Altitude | Up to 15,000 feet |
Storage Altitude | 15,000 feet |
Mean Time Between Failures (MTBF) | 436,034 |
Industrial Automation Control System |
IEC 62443-4-1 IEC 62443-4-2 |
Electromagnetic emissions | FCC 47 CFR Part 15 subpart B Class A EN 55032/CISPR 32 Class A VCCI Class A AS/NZS CISPR 32 Class A CISPR 11 Class A ICES 003 Class A CNS 13438 Class A KN 32 Class A EN 300 386 |
Electromagnetic immunity | CISPR 24 EN 55024 KN 35 EN 61000-4-2 Electro Static Discharge (air 15kV, contact 8kV) EN 61000-4-3 Radiated RF (10V/m UTP, 20V/m STP) EN 61000-4-4 Electromagnetic Fast Transients (4kV) EN 61000-4-5 Surge (2KV/1KV Power, 4KV STP) EN 61000-4-6 Conducted RF (10Vrms UTP) EN 61000-4-10 Damped Oscillatory Magnetic Field (100 A/m) EN 61000-4-16 Conducted CM Disturbances (30V, Cont/300V, 1 sec) EN 61000-4-17 Ripple Immunity DC Power (10%) EN 61000-4-18 Damped Oscillatory Wave (2.5kV, 1MHz) EN-61000-4-29 DC Voltage Dips and interruptions |
Industry standards | EN 61000-6-2 Industrial Immunity EN 61000-6-4 Industrial Emissions EN 61000-6-1 Light Industrial Immunity EN 61326-1 Measurement, Control and Laboratory Equipment IEEE 1613 Electric Power Stations Communications Networking EN/IEC 61850-3 Electric Substations Communications Networking EN50121-4 Railway Signaling and Telecommunications Apparatus EN50155- Railway applications - Rolling stock ODVA Industrial EtherNet/IP NEMA TS 2-2016 IP30 |
Marine I | DNC Certification according to class guideline DNV-CG-0339 Additional Standards: IEC 60945, IACS UR E10 |
Safety standards and certifications |
Information technology equipment: UL/CSA 60950-1, IEC 60950-1 CB with all country deviations UL/CSA 62368-1, IEC 62368-1 CB with all country deviations Industrial floor (control equipment): UL/CSA 61010-2-201 CB report and certificate to IEC/EN 61010-2-201 Hazardous locations: UL121201 (Class l, Div 2, groups A-D) CSA 213 (Class l, Div 2, groups A-D) UL/CSA 60079-0, -15 (Class l, Zone 2, Gc/IIC) IEC 60079-0, -15 IECEx test report (Class l, Zone 2, Gc/IIC) EN 60079-0, -15 ATEX certificate (Class l, Zone 2, Gc/IIC) Cabinet enclosure required |
Humidity | Relative humidity of 5% to 95% non-condensing IEC 60068-2-78 IEC 60068-2-30 |
Shock and vibration | IEC 60068-2-27 (operational shock, 50G, 3ms, half sine) IEC 60068-2-27 (non-operational shock, 65-80G, 9ms, trapezoidal) MIL-STD-810, Method 514.4 IEC 60068-2-6 (vibration-sinusiodal, 5Hz-150Hz) |
Corrosion | IEC 60068-2-52 (salt fog) IEC 60068-2-60 (flowing mixed gas) |
Specifications
Specifications | IE-3300-8U2X-A |
DRAM | 4 GB |
Flash Memory | 1.5 GB |
Hardware | |
PoE power budget | Up to 480W(including expansion module) |
Removable storage | USB (Optional), SD card (Optional) |
Alarms | 2 alarms in, 1 alarm out |
Console ports | 1 RS-232 (via RJ-45), 1 USB Mini Type B |
Power inputs | Dual DC power inputs |
Number of Queues | 8 |
Forwarding Rate | Line rate for all ports and all packet sizes |
Unicast MAC addresses | 8000 |
Jumbo Frames | 8996 bytes |
No. of VLANs | 256 |
IPv4 Indirect routes | 2000 |
IPv6 Indirect routes | 512 |
Internet Group Managament Protocol (IGMP) Multicast Groups | 1000 |
Spanning Tree Protocol (STP) instances |
128 |
Access Control Entries (PACL/VACL/RACL) |
3000 |
SD card capacity (Optional) | 4 GB |
Input Voltage Range | Redundant DC input voltage: 9.6 to 60VDC 48VDC is required for PoE and 54VDC is required for PoE+ / 4PPoE |
Maximum Input Current | 10.5A |
Power Consumption | 42W |
Operating Temperature | -40°C to +70°C (40 LFM vented enclosure) -40°C to +60°C (sealed enclosure) -34°C to +75°C (Min. 200 LFM fan or blower-equipped enclosure) +85°C (type tested for 16 hours) |
Storage Temperature | -40 C to +85 C |
Operating Altitude | Up to 15,000 feet |
Storage Altitude | 15,000 feet |
Mean Time Between Failures (MTBF) | 436,034 |
Industrial Automation Control System |
IEC 62443-4-1 IEC 62443-4-2 |
Electromagnetic emissions | FCC 47 CFR Part 15 subpart B Class A EN 55032/CISPR 32 Class A VCCI Class A AS/NZS CISPR 32 Class A CISPR 11 Class A ICES 003 Class A CNS 13438 Class A KN 32 Class A EN 300 386 |
Electromagnetic immunity | CISPR 24 EN 55024 KN 35 EN 61000-4-2 Electro Static Discharge (air 15kV, contact 8kV) EN 61000-4-3 Radiated RF (10V/m UTP, 20V/m STP) EN 61000-4-4 Electromagnetic Fast Transients (4kV) EN 61000-4-5 Surge (2KV/1KV Power, 4KV STP) EN 61000-4-6 Conducted RF (10Vrms UTP) EN 61000-4-10 Damped Oscillatory Magnetic Field (100 A/m) EN 61000-4-16 Conducted CM Disturbances (30V, Cont/300V, 1 sec) EN 61000-4-17 Ripple Immunity DC Power (10%) EN 61000-4-18 Damped Oscillatory Wave (2.5kV, 1MHz) EN-61000-4-29 DC Voltage Dips and interruptions |
Industry standards | EN 61000-6-2 Industrial Immunity EN 61000-6-4 Industrial Emissions EN 61000-6-1 Light Industrial Immunity EN 61326-1 Measurement, Control and Laboratory Equipment IEEE 1613 Electric Power Stations Communications Networking EN/IEC 61850-3 Electric Substations Communications Networking EN50121-4 Railway Signaling and Telecommunications Apparatus EN50155- Railway applications - Rolling stock ODVA Industrial EtherNet/IP NEMA TS 2-2016 IP30 |
Marine I | DNC Certification according to class guideline DNV-CG-0339 Additional Standards: IEC 60945, IACS UR E10 |
Safety standards and certifications |
Information technology equipment: UL/CSA 60950-1, IEC 60950-1 CB with all country deviations UL/CSA 62368-1, IEC 62368-1 CB with all country deviations Industrial floor (control equipment): UL/CSA 61010-2-201 CB report and certificate to IEC/EN 61010-2-201 Hazardous locations: UL121201 (Class l, Div 2, groups A-D) CSA 213 (Class l, Div 2, groups A-D) UL/CSA 60079-0, -15 (Class l, Zone 2, Gc/IIC) IEC 60079-0, -15 IECEx test report (Class l, Zone 2, Gc/IIC) EN 60079-0, -15 ATEX certificate (Class l, Zone 2, Gc/IIC) Cabinet enclosure required |
Humidity | Relative humidity of 5% to 95% non-condensing IEC 60068-2-78 IEC 60068-2-30 |
Shock and vibration | IEC 60068-2-27 (operational shock, 50G, 3ms, half sine) IEC 60068-2-27 (non-operational shock, 65-80G, 9ms, trapezoidal) MIL-STD-810, Method 514.4 IEC 60068-2-6 (vibration-sinusiodal, 5Hz-150Hz) |
Corrosion | IEC 60068-2-52 (salt fog) IEC 60068-2-60 (flowing mixed gas) |
Accessories
Accessories and License Upgrade PIDs | |
SD-IE-4GB= | IE 4GB SD memory card for IE |
STK-RACK-DINRAIL= | 19 in. DIN Rail mount kit |
IE3300-NW-A= | Network Advantage License for IE3300, Perpetual |
IE3300-DNA-E | Cisco DNA Essentials license for IE3300 Series |
IE3300-DNA-E-3Y | IE 3300 Cisco DNA Essentials, 3 Year Term license |
IE3300-DNA-E-5Y | IE 3300 Cisco DNA Essentials, 5 Year Term license |
IE3300-DNA-E-7Y | IE 3300 Cisco DNA Essentials, 7 Year Term license |
IE3300-DNA-A | Cisco DNA Advantage license for IE3300 Series |
IE3300-DNA-A-3Y | IE 3300 Cisco DNA Advantage, 3 Year Term license |
IE3300-DNA-A-5Y | IE 3300 Cisco DNA Advantage, 5 Year Term license |
IE3300-DNA-A-7Y | IE 3300 Cisco DNA Advantage, 7 Year Term license |
LIC-MRP-MGR-XE= | MRP Ring Manager License |
LIC-MRP-CLIENT-XE= | MRP Ring Client License |
IE 3300 Series Power Supplies | |
PWR-IE50W-AC | 50W AC Power Supply |
PWR-IE50W-AC-IEC= | 50W AC-IEC Power Supply |
PWR-IE50W-AC-L | 50W AC-L Power Supply |
PWR-IE65W-PC-AC | 65W PC-AC Power Supply |
PWR-IE65W-PC-DC | 65W PC-DC Power Supply |
PWR-IE170W-PC- AC | 170W PC-AC Power Supply |
PWR-IE170W-PC- DC | 170W PC-DC Power Supply |
PWR-IE240W-PCAC-L | 240W PCAC-L Power Supply |
PWR-IE480W-PCAC-L | 480W PCAC-L Power Supply |
SFPs | |
GLC-FE-100FX-RGD=* | 100BASE-FX Rugged SFP for Fast Ethernet SFP Ports |
GLC-FE-100LX-RGD* | 100BASE-LX10 Rugged SFP for Fast Ethernet SFP Ports |
GLC-FE-100FX=* | 100BASE-FX SFP for Fast Ethernet SFP Ports |
GLC-FE-100LX=* | 100BASE-LX10 SFP for Fast Ethernet SFP Ports |
GLC-FE-100EX=* | 100BASE-EX for Fast Ethernet SFP Ports |
GLC-FE-100ZX=* | 100BASE-ZX for Fast Ethernet SFP Ports |
GLC-FE-100BX-D=* | 100BASE-BX10-D SFP for Fast Ethernet SFP Ports |
GLC-FE-100BX-U=* | 100BASE-BX10-U SFP for Fast Ethernet SFP Ports |
GLC-SX-MM-RGD= | 1000BASE-SX short wavelength; rugged |
GLC-LX-SM-RGD= | 1000BASE-LX/LH long wavelength; rugged |
GLC-ZX-SM-RGD= | 1000BASE-ZX extended distance; rugged |
GLC-BX40-U-I= | 1000BASE-BX40-U for 40km Single-Fiber Bidirectional Applications; with DOM |
GLC-BX40-D-I= | 1000BASE-BX40-D for 40km Single-Fiber Bidirectional Applications; with DOM |
GLC-BX40-DA-I= | 1000BASE-BX40-D (Alternative) for 40km Single-Fiber Bidirectional Applications; with DOM |
GLC-BX80-U-I= | 1000BASE-BX80-U for 80km Single-Fiber Bidirectional Applications; with DOM |
GLC-BX80-D-I= | 1000BASE-BX80-D for 80km Single-Fiber Bidirectional Applications; with DOM |
GLC-SX-MMD= | 1000BASE-SX short wavelength; with DOM |
GLC-LH-SMD= | 1000BASE-LX/LH long-wavelength; with DOM |
GLC-EX-SMD= | 1000BASE-EX long-wavelength; with DOM |
GLC-ZX-SMD= | 1000BASE-ZX extended distance; with DOM |
GLC-BX-D= | 1000BASE-BX10-D downstream bidirectional single fiber; with DOM |
GLC-BX-U= | 1000BASE-BX10-U upstream bidirectional single fiber; with DOM |
GLC-BX-D-I= | 1000BASE-BX10-D downstream bidirectional single fiber, (IND) rated, with DOM |
GLC-BX-U-I= | 1000BASE-BX10-U upstream bidirectional single fiber, (IND) rated, with DOM |
SFP-GE-S= | Cisco SFP-GE-S Duplex SFP 1Gbps 500m MMF DDM 850nm |
GLC-SX-MM= | Cisco GLCSXMM SFP, Duplex, 1Gbps, 500m, 7.5dB, MMF, 850nm |
GLC-TE= | 1000BASE-T standard |
GLC-T-RGD= | 1000BASE-T standard |
SFP-10G-BXD-I= | 10GBASE-BX10-D Bidirectional for 10km |
SFP-10G-BXU-I= | 10GBASE-BX10-U Bidirectional for 10km |
SFP-10G-BX40D-I= | 10GBASE-BX40-D Bidirectional for 40km |
SFP-10G-BX40U-I= | 10GBASE-BX40-U Bidirectional for 40km |
SFP-10G-SR-X= | Multirate 10GBASE-SR, 10GBASE-SW and OTU2e SFP+ Module for MMF, extended temperature range |
SFP-10G-LR-X= | Multirate 10GBASE-LR, 10GBASE-LW and OTU2e SFP+ Module for SMF, extended temperature range |
SFP-10G-SR= | 10GBASE-SR SFP+ Module for MMF |
SFP-10G-LRM= | 10GBASE-LRM SFP+ Module for MMF and SMF |
SFP-10G-LR= | 10GBASE-LR SFP+ Module for SMF |
SFP-10G-ER= | 10GBASE-ER SFP+ Module for SMF |
SFP-10G-ZR= | Multirate 10GBASE-ZR, 10GBASE-ZW and OTU2e SFP+ Module for SMF |
SFP-H10GB-CUxM= | 10GBASE-CU SFP+ Cable x Meter, passive |
SFP-10G-ER-I= | Multirate 10GBASE-ER, 10GBASE-EW and OTU2e SFP+ Module for SMF, Industrial Temperature range |
SFP-10G-ZR-I= | Multirate 10GBASE-ZR, 10GBASE-ZW and OTU2e SFP+ Module for SMF |
CWDM-SFP10G-1470 | Cisco CWDM 1470-nm SFP+; 10 Gigabit Ethernet |
DWDM-SFP10G-30.33 | 10GBASE-DWDM 1530.33 nm SFP+ (100-GHz ITU grid) |
SFP-10G-LR-S | 10GBASE-LR SFP+ Module for SMF S-Class |
CWDM-SFP-1470 | Cisco CWDM 1470-nm SFP; Gigabit Ethernet and 1 and 2 Gb Fibre Channel |
CWDM-SFP-1610 | Cisco CWDM 1610-nm SFP; Gigabit Ethernet and 1 and 2 Gb Fibre Channel |
CWDM-SFP-1530 | Cisco CWDM 1530-nm SFP; Gigabit Ethernet and 1 and 2-Gb Fibre Channel |
CWDM-SFP-1490 | Cisco CWDM 1490-nm SFP; Gigabit Ethernet and 1 and 2 Gb Fibre Channel |
DWDM-SFP-3033 | 1000BASE-DWDM 1530.33 nm SFP (100-GHz ITU grid) |
DWDM-SFP-3112 | 1000BASE-DWDM 1531.12 nm SFP (100-GHz ITU grid) |
*Supported only on Expansion modules with SFP downlink port option when paired with IE 3300 10G Uplinks Variants. |