CISCO IE-3400-8P2S-E SWITCH

$4,350 $10,773

Description

Cisco IE-3400-8P2S-E Switch

The Cisco IE3400 Rugged Series extends Full Gigabit connectivity to harsh environments such as those in manufacturing, mining, and transportation. Their hardened design and high-density industrial PoE support make them ideal for industrial applications. The IE-3400-8P2S-E is run by the next-generation operating system: Cisco IOS EX. This delivers built-in security features such as secure boot and image signing to protect your network.

Key Features:

  • Network Essentials License
  • PoE/PoE+ enabled
  • 2 x Gigabit Ethernet SFP ports

Properties

Properties Cisco IE-3400-8P2S-E
Description Catalyst IE3400 with 8 GE PoE/PoE+, 2 GE SFP, Adv. Modular, Network Essentials
Product Family Industrial Ethernet 3400
Product Type Ethernet Switch
Switches
Total Ports 10
10/100/1000 RJ45 Copper Ports 8
100/1000 SFP Ports 2
1GE/2.5G RJ45 Copper ports -
Software License (Default) Network Essentials
PoE/PoE (+) budget 240W (base), 360W (with module)
Software Features
Network Essentials
License (Perpetual)
Features
Layer 2 Switching IEEE 802.1, 802.3 standard, NTP, UDLD, CDP, LLDP, unicast MAC filter, PAgP, LACP, VTPv2,
VTPv3, EtherChannel, Q-in-Q tunneling, voice VLAN, PVST+, MSTP, and RSTP
Multicast IGMPv1, v2, v3 snooping, IGMP filtering, IGMP querier
Managament WebUI, MIB, SmartPort, SNMP, syslog, DHCP server, SPAN session, RSPAN, FSPAN,
Express setup, NETCONF, RESTCONF
Security Port security, 802.1x, Dynamic Host Configuration Protocol (DHCP) snooping, dynamic ARP inspection, IP source guard, guest VLAN, MAC authentication bypass, 802.1x multidomain authentication, storm control - unicast, multicast, broadcast, SCP, SSH, SNMPv3, TACACS+, RADIUS server/client, MAC address notification, BPDU guard, Access Lists (PACL,VACL,RACL), SUDI 2099 (Secure Unique Device identifier), Full Flexible NetFlow (FNF), MACsec-128
Quality of Service (QoS) Ingress policing, rate limit, egress queuing and shaping, auto QoS
IPv6 IPv6 host support, SNMP over IPv6, HTTP/HTTP(s) over IPv6, SNMP over IPv6, Syslog over IPv6, DHCPv6 relay source, DHCPv6 bulk lease query (RFC 5460), IPv6 stateless Auto Config SCP/SSH, Radius, TACACS+, NTP over IPv6, IPv6 VRF aware BGPv6, IPV6 ND cache expire, IPv6 support for TFTP, IPv6 DNS transport, IPv6 QoS, IPv6 FHS RA Guard, IPv6 FHS DHCPv6 Guard
Layer 3 Routing Inter-VLAN routing, Static routing
Utility Dying gasp, SCADA protocol classification - GOOSE messaging, MODBUS TCP/IP
Industrial Ethernet CIP Ethernet/IP, IEEE 1588 PTP v2 (default and power), PROFINET
Redundancy Resilient Ethernet Protocol (REP) ring, PROFINET-Media Redundancy Protocol (MRP), REP Preferred, Fast REP
Automation YANG, NETCONF, RESTCONF
Industrial Management Layer 2 switching with 1:1 switch Network Address Translation (L2NAT)
IOx Container (Native docker)
Dimensions (HxWxD) Inches 6 in. X 3.6 in. X 5.3 in.
15.2 cm. x 9.1 cm. x 13.5 cm
Weight 5.0 lbs (2.3 Kg)
Mounting DIN Rail

 

Specifications

Specifications IE-3400-8P2S-E
DRAM 4 GB
Flash Memory 1.5 GB
Hardware
PoE power budget 480W (including expansion module)
Removable storage USB (Optional), SD card (Optional)
Alarms 2 alarms in, 1 alarm out
Console ports 1 RS-232 (via RJ-45), 1 USB Mini Type B
Power inputs Dual DC power inputs
Number of Queues 8
Forwarding Rate Line rate for all ports and all packet sizes
Unicast MAC addresses 8000
Jumbo Frames 2000 bytes
No. of VLANs 256
IPv4 Indirect routes 2000
IPv6 Indirect routes 512
Internet Group Managament Protocol (IGMP) Multicast Groups 1000
Spanning Tree Protocol (STP)
instances
128
Access Control Entries
(PACL/VACL/RACL)
3000
SD card capacity (Optional) 4 GB
Input Voltage Range Redundant DC input voltage: 9.6 to 60VDC
48VDC is required for PoE and 54VDC is required for PoE+
Maximum Input Current 10.6A
Power Consumption 47W
Operating Temperature -40°C to +70°C (40 LFM vented enclosure)
-40°C to +60°C (sealed enclosure)
-34°C to +75°C (Min. 200 LFM fan or blower-equipped enclosure)
+85°C (type tested for 16 hours)
Storage Temperature -40 C to +85 C
Operating Altitude Up to 15,000 feet
Storage Altitude 15,000 feet
Mean Time Between Failures (MTBF) 401,313
Industrial Automation Control
System
IEC 62443-4-1
IEC 62443-4-2
Electromagnetic emissions FCC 47 CFR Part 15 subpart B Class A
EN 55032/CISPR 32 Class A
VCCI Class A
AS/NZS CISPR 32 Class A
CISPR 11 Class A
ICES 003 Class A
CNS 13438 Class A
KN 32 Class A
EN 300 386
Electromagnetic immunity CISPR 24
EN 55024
KN 35
EN 61000-4-2 Electro Static Discharge (air 15kV, contact 8kV)
EN 61000-4-3 Radiated RF (10V/m UTP, 20V/m STP)
EN 61000-4-4 Electromagnetic Fast Transients (4kV)
EN 61000-4-5 Surge (2KV/1KV Power, 4KV STP)
EN 61000-4-6 Conducted RF (10Vrms UTP)
EN 61000-4-10 Damped Oscillatory Magnetic Field (100 A/m)
EN 61000-4-16 Conducted CM Disturbances (30V, Cont/300V, 1 sec)
EN 61000-4-17 Ripple Immunity DC Power (10%)
EN 61000-4-18 Damped Oscillatory Wave (2.5kV, 1MHz)
EN-61000-4-29 DC Voltage Dips and interruptions
Industry standards EN 61000-6-2 Industrial Immunity
EN 61000-6-4 Industrial Emissions
EN 61000-6-1 Light Industrial Immunity
EN 61326-1 Measurement, Control and Laboratory Equipment
IEEE 1613 Electric Power Stations Communications Networking
EN/IEC 61850-3 Electric Substations Communications Networking
EN50121-4 Railway Signaling and Telecommunications Apparatus
EN50155- Railway applications - Rolling stock
ODVA Industrial EtherNet/IP
NEMA TS 2-2016
IP30
Marine I DNC Certification according to class guideline DNV-CG-0339
Additional Standards:
IEC 60945, IACS UR E10
Safety standards and
certifications
Information technology equipment:
UL/CSA 60950-1, IEC 60950-1 CB with all country deviations
UL/CSA 62368-1, IEC 62368-1 CB with all country deviations
Industrial floor (control equipment):
UL/CSA 61010-2-201
CB report and certificate to IEC/EN 61010-2-201
Hazardous locations:
UL121201 (Class l, Div 2, groups A-D)
CSA 213 (Class l, Div 2, groups A-D)
UL/CSA 60079-0, -15 (Class l, Zone 2, Gc/IIC)
IEC 60079-0, -15 IECEx test report (Class l, Zone 2, Gc/IIC)
EN 60079-0, -15 ATEX certificate (Class l, Zone 2, Gc/IIC) Cabinet enclosure required
Humidity Relative humidity of 5% to 95% non-condensing
IEC 60068-2-78
IEC 60068-2-30
Shock and vibration IEC 60068-2-27 (operational shock, 50G, 3ms, half sine)
IEC 60068-2-27 (non-operational shock, 65-80G, 9ms, trapezoidal)
MIL-STD-810, Method 514.4
IEC 60068-2-6 (vibration-sinusiodal, 5Hz-150Hz)
Corrosion IEC 60068-2-52 (salt fog)
IEC 60068-2-60 (flowing mixed gas)

Accessories

Accessories and License Upgrade PIDs
SD-IE-4GB= IE 4GB SD memory card for IE
STK-RACK-DINRAIL= STK-RACK-DINRAIL=
IE3400-NW-A= Network Advantage License for IE3400, Perpetual
IE3400-DNA-E Cisco DNA Essentials license for IE3400 Series
IE3400-DNA-E-3Y IE 3400 Cisco DNA Essentials, 3 Year Term license
IE3400-DNA-E-5Y IE 3400 Cisco DNA Essentials, 5 Year Term license
IE3400-DNA-E-7Y IE 3400 Cisco DNA Essentials, 7 Year Term license
IE3400-DNA-A Cisco DNA Advantage license for IE3400 Series
IE3400-DNA-A-3Y IE 3400 Cisco DNA Advantage, 3 Year Term license
IE3400-DNA-A-5Y IE 3400 Cisco DNA Advantage, 5 Year Term license
IE3400-DNA-A-7Y IE 3400 Cisco DNA Advantage, 7 Year Term license
LIC-MRP-MGR-XE= MRP Ring Manager License
LIC-MRP-CLIENT-XE= MRP Ring Client License
IE 3400 Series Power Supplies
PWR-IE50W-AC 50W AC Power Supply
PWR-IE50W-AC-IEC= 50W AC-IEC Power Supply
PWR-IE50W-AC-L 50W AC-L Power Supply
PWR-IE65W-PC-AC 65W PC-AC Power Supply
PWR-IE65W-PC-DC 65W PC-DC Power Supply
PWR-IE170W-PC- AC 170W PC-AC Power Supply
PWR-IE170W-PC- DC 170W PC-DC Power Supply
PWR-IE240W-PCAC-L 240W PCAC-L Power Supply
PWR-IE480W-PCAC-L 480W PCAC-L Power Supply
SFPs
GLC-FE-100FX-RGD= 100BASE-FX Rugged SFP for Fast Ethernet SFP Ports
GLC-FE-100LX-RGD 100BASE-LX10 Rugged SFP for Fast Ethernet SFP Ports
GLC-FE-100FX= 100BASE-FX SFP for Fast Ethernet SFP Ports
GLC-FE-100LX= 100BASE-LX10 SFP for Fast Ethernet SFP Ports
GLC-FE-100EX= 100BASE-EX for Fast Ethernet SFP Ports
GLC-FE-100ZX= 100BASE-ZX for Fast Ethernet SFP Ports
GLC-FE-100BX-D= 100BASE-BX10-D SFP for Fast Ethernet SFP Ports
GLC-FE-100BX-U= 100BASE-BX10-U SFP for Fast Ethernet SFP Ports
GLC-SX-MM-RGD= 1000BASE-SX short wavelength; rugged
GLC-LX-SM-RGD= 1000BASE-LX/LH long wavelength; rugged
GLC-ZX-SM-RGD= 1000BASE-ZX extended distance; rugged
GLC-BX40-U-I= 1000BASE-BX40-U for 40km Single-Fiber Bidirectional Applications; with DOM
GLC-BX40-D-I= 1000BASE-BX40-D for 40km Single-Fiber Bidirectional Applications; with DOM
GLC-BX40-DA-I= 1000BASE-BX40-D (Alternative) for 40km Single-Fiber Bidirectional Applications; with DOM
GLC-BX80-U-I= 1000BASE-BX80-U for 80km Single-Fiber Bidirectional Applications; with DOM
GLC-BX80-D-I= 1000BASE-BX80-D for 80km Single-Fiber Bidirectional Applications; with DOM
GLC-SX-MMD= 1000BASE-SX short wavelength; with DOM
GLC-LH-SMD= 1000BASE-LX/LH long-wavelength; with DOM
GLC-EX-SMD= 1000BASE-EX long-wavelength; with DOM
GLC-ZX-SMD= 1000BASE-ZX extended distance; with DOM
GLC-BX-D= 1000BASE-BX10-D downstream bidirectional single fiber; with DOM
GLC-BX-U= 1000BASE-BX10-U upstream bidirectional single fiber; with DOM
GLC-BX-D-I= 1000BASE-BX10-D downstream bidirectional single fiber, (IND) rated, with DOM
GLC-BX-U-I= 1000BASE-BX10-U upstream bidirectional single fiber, (IND) rated, with DOM
SFP-GE-S= Cisco SFP-GE-S Duplex SFP 1Gbps 500m MMF DDM 850nm
SFP-GE-L= 1000BASE-LX/LH SFP (DOM)
SFP-GE-Z= Cisco 1000BASE-ZX SFP transceiver module for SMF
GLC-SX-MM= Cisco GLC_x0090_SX_x0090_MM SFP, Duplex, 1Gbps, 500m, 7.5dB, MMF, 850nm
GLC-LH-SM= Cisco Glc Lh Sm 1000Base Lh Sm Sfp Transceiver Module
GLC-ZX-SM= Cisco 1000BASE-ZX SFP transceiver module for SMF, 1550-nm wavelength,
commercial operating temperature range.
GLC-TE= 1000BASE-T standard
GLC-T-RGD= 1000BASE-T standard
CWDM-SFP-1470 Cisco CWDM 1470-nm SFP; Gigabit Ethernet and 1 and 2 Gb Fibre Channel
CWDM-SFP-1610 Cisco CWDM 1610-nm SFP; Gigabit Ethernet and 1 and 2 Gb Fibre Channel
CWDM-SFP-1530 Cisco CWDM 1530-nm SFP; Gigabit Ethernet and 1 and 2-Gb Fibre Channel
CWDM-SFP-1490 Cisco CWDM 1490-nm SFP; Gigabit Ethernet and 1 and 2 Gb Fibre Channel
DWDM-SFP-3033 1000BASE-DWDM 1530.33 nm SFP (100-GHz ITU grid)
DWDM-SFP-3112 1000BASE-DWDM 1531.12 nm SFP (100-GHz ITU grid)

Domestic Shipping

All products from Gaia Consulting Services are shipped Monday through Friday via trusted carriers such as UPS, FedEx, or USPS. We are pleased to offer free delivery on all orders over $100 within the United States. Orders typically take 1-6 business days to arrive, depending on your location. For orders that do not qualify for free delivery, shipping rates are calculated based on factors such as the shipping carrier, method, package weight, and destination. Please note that additional surcharges may apply for shipments to Hawaii, Alaska, Puerto Rico, and APO/FPO addresses. While we strive to ship orders on the same day they are placed, any delays or cancellations will be promptly communicated to you.

International Shipping

Gaia Consulting Services also offers international shipping to customers worldwide. However, please be aware that we adhere to all international trade laws and regulations and do not ship to countries currently under embargo by the United States.

Shipping Carriers and Transit Times

For international shipments, we utilize reliable carriers such as UPS, FedEx, and DHL to ensure your orders arrive safely and on time. Transit times typically range between 7-15 business days, depending on the destination and chosen shipping method. Please note that customs clearance processes may cause delays, which are beyond our control.

Customs, Duties, and Taxes

Customers outside the United States are responsible for any customs duties, taxes, or additional fees imposed by their country's customs authorities. Gaia Consulting Services cannot predict or control these charges and advises customers to familiarize themselves with their country's import regulations before placing an order. Please note that these charges are not included in the item price or shipping costs.

Order Processing

We strive to process and ship orders quickly and efficiently. If any issues arise with your order, we will notify you promptly to keep you informed of its status.

Shipping Addresses

To ensure smooth delivery, please provide an accurate and complete shipping address during checkout. Gaia Consulting Services cannot be held liable for orders shipped to incorrect addresses due to customer error. If you need to modify your shipping address after placing an order, please contact us immediately. Please note that we may be unable to change the shipping address if your order has already been processed.