CISCO PWR-C1-1100WAC POWER SUPPLY
$1,519
$2,329.87
Uninterrupted Power Supply by Cisco PWR-C1-1100WAC Power Supply
Cisco PWR-C1-1100WAC Power Supply is the right choice for power supply to Catalyst 3850-48F-E and giving uninterrupted power supply experience to specific Cisco switch models.
Key Benefits of Cisco PWR-C1-1100WAC Power Supply
Cisco PWR-C1-1100WAC Power Supply requires 50-60 Hz frequency and AC 115-240 V input voltage for optimum performance. This 1100-watt AC power supply spare plug-in module features Power IEC 320 EN 60320 C16 connector.
Properties
Properties | Cisco PWR-C1-1100WAC |
Description | 1100WAC power supply |
Product Family | Catalyst 9300 |
Product Type | Power Supply |
Power supply rated maximum | 1100W |
Total output BTU (note: 1000 BTU/hr = 293W) | 3793 BTU/hr, 1100W |
Input-voltage range and frequency | 115V to 240 VAC, 50 to 60 Hz |
Input current | 12-6A |
Output ratings | -56V at 19.64A |
Output holdup time | 10 ms minimum at 100VAC |
Power-supply input receptacles | IEC 320-C16 (IEC60320-C16) |
Power cord rating | 15A |
Physical specifications | (H x W x D): 1.58 x 3.25 x 13.7 in Weight: 3.1 lb (1.4 kg) |
Specifications
Specifications | PWR-C1-1100WAC |
Power connectors | Customers can provide power to a switch by using the internal power at the back of the switch Internal power supply connector: The internal power supply is an auto-ranging unit. It supports input voltages between 100 (115 for 1100WAC) and 240 VAC. Use the supplied AC power cord to connect the AC power connector to an AC power outlet |
LED indicators | AC OK: Input power to the power supply is OK PS OK: Output power from the power supply is OK |
Operating temperature | Normal operating temperature* and altitudes: -5°C to +45°C, up to 5000 feet (1500m) -5°C to +40°C, up to 10,000 feet (3000m) *Minimum ambient temperature for cold start is 32°F (0°C) Short-term* exceptional conditions: -5°C to +50°C, up to 5000 feet (1500m) -5°C to +45°C, up to 10,000 feet (3000m) -5°C to +45°C, at sea level with single fan failure *Not more than following in one-year period: 96 consecutive hours, or 360 hours total, or 15 occurrences |
Storage temperature | -40° to 158°F (-40° to 70°C) |
Altitude | 10,000 ft. (3000 meters), up to 45°C |
Relative humidity operating and nonoperating noncondensing | 5% to 90% noncondensing |
EMI and EMC compliance | FCC Part 15 (CFR 47) Class A ICES-003 Class A EN 55032 Class A CISPR 32 Class A AS/NZS 3548 Class A BSMI Class A (AC input models only) VCCI Class A EN 55024, EN300386, EN 61000-3-2, EN 61000-3-3 EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6 |