Use Cisco PWR-C1-715WAC Power Supply for High-Performance
Cisco PWR-C1-715WAC Power Supply is designed to efficiently provide power to Cisco catalyst switch. This plug-in module fits perfectly in compatible Cisco Catalyst Series Switches.
Key Benefits of Cisco PWR-C1-715WAC Power Supply
Cisco PWR-C1-715WAC Power Supply can autorange units to support input voltages from 100 through 240 VAC. Find a power cord for connection to an AC power outlet. It delivers a 715-watt redundant power supply at AC 100-240 Watt for user convenience and high performance.
Properties
Properties | Cisco PWR-C1-715WAC |
Description | 715WAC power supply |
Product Family | Catalyst 9300 |
Product Type | Power Supply |
Power supply rated maximum | 715W |
Total output BTU (note: 1000 BTU/hr = 293W) | 2465 BTU/hr, 715W |
Input-voltage range and frequency | 100 to 240 VAC, 50 to 60 Hz |
Input current | 10-5A |
Output ratings | -56V at 12.8A |
Output holdup time | 16.7 ms minimum at 100VAC |
Power-supply input receptacles | IEC 320-C16 (IEC60320-C16) |
Power cord rating | 15A |
Physical specifications | (H x W x D): 1.58 x 3.25 x 12.20 in Weight: 2.6 lb (1.2 kg) |
Specifications
Specifications | PWR-C1-715WAC |
Power connectors | Customers can provide power to a switch by using the internal power at the back of the switch Internal power supply connector: The internal power supply is an auto-ranging unit. It supports input voltages between 100 (115 for 1100WAC) and 240 VAC. Use the supplied AC power cord to connect the AC power connector to an AC power outlet |
LED indicators | AC OK: Input power to the power supply is OK PS OK: Output power from the power supply is OK |
Operating temperature | Normal operating temperature* and altitudes: -5°C to +45°C, up to 5000 feet (1500m) -5°C to +40°C, up to 10,000 feet (3000m) *Minimum ambient temperature for cold start is 32°F (0°C) Short-term* exceptional conditions: -5°C to +50°C, up to 5000 feet (1500m) -5°C to +45°C, up to 10,000 feet (3000m) -5°C to +45°C, at sea level with single fan failure *Not more than following in one-year period: 96 consecutive hours, or 360 hours total, or 15 occurrences |
Storage temperature | -40° to 158°F (-40° to 70°C) |
Altitude | 10,000 ft. (3000 meters), up to 45°C |
Relative humidity operating and nonoperating noncondensing | 5% to 90% noncondensing |
EMI and EMC compliance | FCC Part 15 (CFR 47) Class A ICES-003 Class A EN 55032 Class A CISPR 32 Class A AS/NZS 3548 Class A BSMI Class A (AC input models only) VCCI Class A EN 55024, EN300386, EN 61000-3-2, EN 61000-3-3 EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6 |