CISCO PWR-IE50W-AC-IEC POWER SUPPLY
$275
$555.52
Cisco PWR-IE50W-AC-IEC Power Supply
Cisco's industrial din-rail power supply portfolio provides versatile options for powering industrial networking equipment. They support high-capacity Power over Ethernet (PoE) and are available with conformal coating options. The PWR-IE50W-AC-IEC is 50W AC to DC power supply with IEC connector specific to Cisco Industrial Ethernet (IE)3000 series switches which has 50 watts of power and is DIN rail-mountable.
Key Features:
- 50W
- IEC 60320 C14
- For Cisco IE3000 series
For detailed specifications, refer to the Cisco PPWR-IE50W-AC-IEC datasheet in the tabs.
Properties
Properties | Cisco PWR-IE50W-AC-IEC |
Description | Expansion power module for IE-3000-4TC and IE-3000-8TC switches |
Product Family | Industrial Ethernet 3000 |
Product Type | Power Supply |
Configurations | Expansion Power Module for Cisco IE-3000-4TC, IE-3000-8TC, IE-3000-4TC-E and IE-3000-8TC-E switches, supports Input AC 100-240V/1.25A 50-60Hz, Output DC 24V/2.1A, IEC Plug, DIN-Rail Mount |
Dimensions (HxWxD) Inches | 2.0W x 5.8H x 4.4D (51mm W x 147mm H x 112mm D) |
Weight | 1.4 lb (0.65kg) |
Input voltage and currents supported | 100-240VAC/1.25A, 50-60Hz |
Specifications
Specifications | PWR-IE50W-AC-IEC |
Mean Time Between Failures (MTBF) | 1,662,359 |
Operating Temperature | -40C to +75C -40C to +70C (Vented Enclosure 40 LFM Air Flow) -40C to +60C (Sealed Enclosure 0 LFM Air Flow) -24C to +75C (Fan or Blower equipped Enclosure 200 LFM Air Flow) -40C to +85C (IEC 60068-2-2 Environmental Type Testing 16 hours) |
Storage Temperature | -40 C to +85 C |
Operating Altitude | Up to 13,000 ft (3963m) |
Storage Altitude | Up to 15,000 ft (4573m) |
Standard safety certifications | UL 60950-1 CSA C22.2 No. 60950-1 TUV/GS to EN 60950-1 CB to IEC 60950-1 with all country deviations NOM |
Electromagnetic emissions | FCC Part 15 Class A EN 55022 CISPR 22 CISPR11 VCCI Class A AS/NZS 3548 Class A CNS 13438 Class A KN 22 Class A |
Electromagnetic immunity | EN 55024 AS/NZS CISPR 24 KN 24 IEC/EN 61000-4-2 (Electro Static Discharge) IEC/EN 61000-4-3 (Radiated Immunity) IEC/EN 61000-4-4 (Fast Transients) IEC/EN 61000-4-5 (Surge) IEC/EN 61000-4-6 (Conducted Immunity) IEC/EN 61000-4-8 (Power Frequency Magnetic Field Immunity) IEC/EN 61000-4-9 (Pulse Magnetic Field Immunity) IEC/EN 61000-4-10 (Oscillatory Magnetic Field Immunity) IEC/EN 61000-4-11 (AC power Voltage Immunity) IEC/EN 61000-4-16 (Low Frequency Conducted CM Disturbances) IEC/EN 61000-4-17 (Ripple on DC Input Power) IEC/EN 61000-4-18 (Damped Oscillatory Wave) IEC/EN 61000-4-29 (Voltage Dips Immunity, DC power) IEEE C37.90 (Surge) IEEE C37.90.1 (Fast Transients) IEEE C37.90.2 (Radiated Immunity) IEEE C37.90.3 (Electro Static Discharge) |
Mechanical stability | IEC 60628-2-27 Shock 20g (operational), 30g (nonoperational) |
Industry specifications | EN 61131-2 Programmable Controllers (EMC/EMI, environmental, mechanical) IEEE 1613 Power Station and Substation Networking Devices IEC 61850-3 Power Station and Substation Communication Networks and Systems EN 61326-1 Electrical Equipment for Measurement, Control and Laboratory Use - EMC EN 61000-6-1 Immunity for Light Industrial Environments EN 61000-6-2 Immunity for Industrial Environments EN 61000-6-4 Emissions for Industrial Environments TS 61000-6-5 EMC Immunity for Power Station and Substation EN 50155 Railway, Electronic Equipment on Rolling Stock (EMI/EMC, environmental, mechanical) EN 50121-3-2 Railway, Electromagnetic Compatibility on Rolling Stock EN 50121-4 Railway, Emission and Immunity of Signaling and Telecommunications Apparatus EN 60945 Maritime Navigation and Radio-communication Equipment and Systems IEC 60533 Shipboard Electrical and Electronic Installation EMC Marine Type Approval (BV, DNV, Korean Register, Lloyd Register) NEMA TS-2 (EMC, environmental, mechanical) ABB Industrial IT certification ODVA Industrial EtherNet/IP support PROFINETv2 support Directive 2011/65/EU RoHS IP20 |
Hazardous locations | UL/CSA 60079-0, -15 (Class 1, Div 2 A-D) (requires cabinet enclosure) EN 60079-0, -15 ATEX Certification (Class 1, Zone 2 A-D) (requires cabinet enclosure) IEC 60079-0, -15 (Test report only) (requires cabinet enclosure) UL 508 CSA C22.2 No. 142 |
Humidity | Relative humidity: 5% to 95% non-condensing |