CISCO PWR-C1-350WAC-P POWER SUPPLY
$300
$768.88
Cisco PWR-C1-350WAC-P Power Supply
The Cisco PWR-C1-350WAC-P= power supply is tailored to the Catalyst 3850 and Catalyst 9300 series switches. It comes with an 80+ platinum rating, which guarantees top-notch energy efficiency and environmental certification. The power supply is also equipped with sophisticated cooling mechanisms that improve the reliability and longevity of the equipment, and it can deliver up to 350W of output power.
Key Features:
- 80+ Platinum-rated
- Output power 350W
- Lifetime Warranty
Properties
Properties | Cisco PWR-C1-350WAC-P |
Description | 350WAC Platinum-rated power supply |
Product Family | Catalyst 9300 |
Product Type | Power Supply |
Power supply rated maximum | 350W |
Total output BTU (note: 1000 BTU/hr = 293W) | 1194 BTU/hr, 350W |
Input-voltage range and frequency | 100 to 240 VAC, 50 to 60 Hz |
Input current | 4-2A |
Output ratings | -56V at 6.25A |
Output holdup time | 20 ms minimum at 100VAC |
Power-supply input receptacles | IEC 320-C14 (IEC60320-C14) |
Power cord rating | 10A |
Physical specifications | (H x W x D): 1.58 x 3.25 x 12.20 in Weight: 2.3 lb (1.2 kg) |
Specifications
Specifications | PWR-C1-350WAC-P |
Mean Time Between Failures MTBF (hours) | 1,335,012 (ranges from 1.3M to 3.1M depending on temperature, input voltage and vendor) |
Power connectors | Customers can provide power to a switch by using the internal power at the back of the switch Internal power supply connector: The internal power supply is an auto-ranging unit. It supports input voltages between 100 (115 for 1100WAC) and 240 VAC. Use the supplied AC power cord to connect the AC power connector to an AC power outlet |
LED indicators | AC OK: Input power to the power supply is OK PS OK: Output power from the power supply is OK |
Operating temperature | Normal operating temperature* and altitudes: -5°C to +45°C, up to 5000 feet (1500m) -5°C to +40°C, up to 10,000 feet (3000m) *Minimum ambient temperature for cold start is 32°F (0°C) Short-term* exceptional conditions: -5°C to +50°C, up to 5000 feet (1500m) -5°C to +45°C, up to 10,000 feet (3000m) -5°C to +45°C, at sea level with single fan failure *Not more than following in one-year period: 96 consecutive hours, or 360 hours total, or 15 occurrences |
Storage temperature | -40° to 158°F (-40° to 70°C) |
Altitude | 10,000 ft. (3000 meters), up to 45°C |
Relative humidity operating and nonoperating noncondensing | 5% to 90% noncondensing |
EMI and EMC compliance | FCC Part 15 (CFR 47) Class A ICES-003 Class A EN 55032 Class A CISPR 32 Class A AS/NZS 3548 Class A BSMI Class A (AC input models only) VCCI Class A EN 55024, EN300386, EN 61000-3-2, EN 61000-3-3 EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6 |