CISCO PWR-RGD-AC-DC POWER SUPPLY
$545
$1,182.89
Cisco PWR-RGD-AC-DC Power Supply
The Cisco PWR-RGD-AC-DC is a rugged High Voltage AC or DC Power Source designed with the Cisco Industrial Ethernet CGS 2520 Series, which can also be used in the CGR 2010 router. It delivers reliable and stable power with a capacity of 150W. The module is a hot plug with high PoE /PoE+ support.
Key Features:
- High PoE+
- Output power 150W
- CGS 2520 Series
The tabs contain the Cisco PWR-RGD-AC-DC datasheet with all the specifics you need.
Properties
Properties | Cisco PWR-RGD-AC-DC |
Description | Power supply, hot-plug / redundant (plug-in module), AC 100-240/ DC 100-250 V, 150 Watt, for Cisco 2010, CGS 2520; Industrial Ethernet 3010 |
Product Family | Industrial Ethernet 3000 |
Product Type | Power Supply |
Dimensions (HxWxD) Inches | 1.58 x 7 x 5 in. (4 x 17.8 x 12.7 cm) (without mounting flanges) |
Weight | 2.55 lb (1.15 kg) |
Maximum output power | 150 W |
Input current | AC: 2.2 to 0.7 A, 85 to 265 VAC DC: 2.5 to 0.6 A, 88 to 300 VDC |
Total input BTU | AC: 638 BTUs per hour DC: 750 BTUs per hour |
Nominal input voltage | 100 to 240 VAC, 50 to 60 Hz 100 to 250 VDC |
Absolute maximum (short term) input voltage |
85 to 265 VAC, 47 to 63 Hz
|
Specifications
Specifications | PWR-RGD-AC-DC |
Operating Temperature | 40 to 140°F (40 to 60°C) |
Storage Temperature | -40 C to +85 C |
Operating Altitude | Up to 10,000 ft (3049 m) |
Relative humidity | 5 to 95% (noncondensing) |
Standard safety certifications | UL 60950-1 CSA C22.2 No. 60950-1 TUV/GS to EN 60950-1 CB to IEC 60950-1 with all country deviations NOM |
Electromagnetic emissions | FCC Part 15 Class A EN 55022 CISPR 22 CISPR11 VCCI Class A AS/NZS 3548 Class A CNS 13438 Class A KN 22 Class A |
Electromagnetic immunity | EN 55024 AS/NZS CISPR 24 KN 24 IEC/EN 61000-4-2 (Electro Static Discharge) IEC/EN 61000-4-3 (Radiated Immunity) IEC/EN 61000-4-4 (Fast Transients) IEC/EN 61000-4-5 (Surge) IEC/EN 61000-4-6 (Conducted Immunity) IEC/EN 61000-4-8 (Power Frequency Magnetic Field Immunity) IEC/EN 61000-4-9 (Pulse Magnetic Field Immunity) IEC/EN 61000-4-10 (Oscillatory Magnetic Field Immunity) IEC/EN 61000-4-11 (AC power Voltage Immunity) IEC/EN 61000-4-16 (Low Frequency Conducted CM Disturbances) IEC/EN 61000-4-17 (Ripple on DC Input Power) IEC/EN 61000-4-18 (Damped Oscillatory Wave) IEC/EN 61000-4-29 (Voltage Dips Immunity, DC power) IEEE C37.90 (Surge) IEEE C37.90.1 (Fast Transients) IEEE C37.90.2 (Radiated Immunity) IEEE C37.90.3 (Electro Static Discharge) |
Mechanical stability | IEC 60628-2-27 Shock 20g (operational), 30g (nonoperational) |
Industry specifications | EN 61131-2 Programmable Controllers (EMC/EMI, environmental, mechanical) IEEE 1613 Power Station and Substation Networking Devices IEC 61850-3 Power Station and Substation Communication Networks and Systems EN 61326-1 Electrical Equipment for Measurement, Control and Laboratory Use - EMC EN 61000-6-1 Immunity for Light Industrial Environments EN 61000-6-2 Immunity for Industrial Environments EN 61000-6-4 Emissions for Industrial Environments TS 61000-6-5 EMC Immunity for Power Station and Substation EN 50155 Railway, Electronic Equipment on Rolling Stock (EMI/EMC, environmental, mechanical) EN 50121-3-2 Railway, Electromagnetic Compatibility on Rolling Stock EN 50121-4 Railway, Emission and Immunity of Signaling and Telecommunications Apparatus EN 60945 Maritime Navigation and Radio-communication Equipment and Systems IEC 60533 Shipboard Electrical and Electronic Installation EMC Marine Type Approval (BV, DNV, Korean Register, Lloyd Register) NEMA TS-2 (EMC, environmental, mechanical) ABB Industrial IT certification ODVA Industrial EtherNet/IP support PROFINETv2 support Directive 2011/65/EU RoHS IP20 |
Hazardous locations | UL/CSA 60079-0, -15 (Class 1, Div 2 A-D) (requires cabinet enclosure) EN 60079-0, -15 ATEX Certification (Class 1, Zone 2 A-D) (requires cabinet enclosure) IEC 60079-0, -15 (Test report only) (requires cabinet enclosure) UL 508 CSA C22.2 No. 142 |
Humidity | Relative humidity: 5% to 95% non-condensing |