CISCO PWR-C1-715WDC POWER SUPPLY
$898
$1,505.25
Cisco PWR-C1-715WDC Power Supply
The PWR-C1-715WDC is a hot-plug power supply provides a power of 715 watts. The Cisco DC Config 1 Power Supply is designed to power the Cisco Catalyst 3850 Series switches.
Key Features:
- 715W
- DC Config 1
- For Catalyst 3850 Series
For detailed specifications, refer to the PWR-C1-715WDC datasheet in the tabs.
Properties
Properties | Cisco PWR-C1-715WDC |
Description | 715WDC power supply |
Product Family | Catalyst 9300 |
Product Type | Power Supply |
Power supply rated maximum | 715W |
Total output BTU (note: 1000 BTU/hr = 293W) | 2440 BTU/hr |
Input-voltage range and frequency | -36V to -72 VDC |
Input current | 24-12A |
Output ratings | -56V at 12.8A |
Output holdup time | 2 ms minimum at -48Vdc |
Power-supply input receptacles | Right angle barrier style terminal block |
Power cord rating | 25A@100VDC |
Physical specifications | (H x W x D): 1.58 x 3.25 x 12.20 in Weight: 2.2 lb (1kg) |
Specifications
Specifications | PWR-C1-715WDC |
Mean Time Between Failures MTBF (hours) | 1,812,103 (-48V input at 40C and vendor Delta) |
Power connectors | Customers can provide power to a switch by using the internal power at the back of the switch Internal power supply connector: The internal power supply is an auto-ranging unit. It supports input voltages between 100 (115 for 1100WAC) and 240 VAC. Use the supplied AC power cord to connect the AC power connector to an AC power outlet |
LED indicators | AC OK: Input power to the power supply is OK PS OK: Output power from the power supply is OK |
Operating temperature | Normal operating temperature* and altitudes: -5°C to +45°C, up to 5000 feet (1500m) -5°C to +40°C, up to 10,000 feet (3000m) *Minimum ambient temperature for cold start is 32°F (0°C) Short-term* exceptional conditions: -5°C to +50°C, up to 5000 feet (1500m) -5°C to +45°C, up to 10,000 feet (3000m) -5°C to +45°C, at sea level with single fan failure *Not more than following in one-year period: 96 consecutive hours, or 360 hours total, or 15 occurrences |
Storage temperature | -40° to 158°F (-40° to 70°C) |
Altitude | 10,000 ft. (3000 meters), up to 45°C |
Relative humidity operating and nonoperating noncondensing | 5% to 90% noncondensing |
EMI and EMC compliance | FCC Part 15 (CFR 47) Class A ICES-003 Class A EN 55032 Class A CISPR 32 Class A AS/NZS 3548 Class A BSMI Class A (AC input models only) VCCI Class A EN 55024, EN300386, EN 61000-3-2, EN 61000-3-3 EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6 |